Venting And Installation - White Mountain Hearth DV25IN33L Installation Instructions And Owner's Manual

Direct vent gas fireplace heater
Table of Contents

Advertisement

TERMINATION CAP
(DVKI KIT)
ROUND CO-LINEAR TO
CO-AXIAL ADAPTOR
OPTIONAL ON/OFF
SWITCH LOCATION
OPTIONAL
LOW VOLTAGE
WIRES
BLOWER
POWER CORD
Page 12

VENTING AND INSTALLATION

RECTANGULAR
TERMINATION CAP
(DVVK3FV KIT)
ROUND
VENT CLAMPS
RETAINER SCREWS MAY
BE INSTALLED THROUGH
THE VENT CLAMPS TO
ENSURE POSITIVE SECUREMENT
OF VENTING.
INTAKE VENT
FLUE EXHAUST VENT
VENT CLAMPS
Figure 8
NOTE: LONG EXTENSION
TUBE FOR INLET VENT
CONNECTION.
USE HIGH TEMP
SEALANT ON VENT
CONNECTIONS
10' MINIMUM
35' MAXIMUM
OPTIONAL ON/OFF
SWITCH LOCATION
USE HIGH TEMP
SEALANT ON VENT
CONNECTIONS
SCREWS ADDED THROUGH
VENT CLAMPS TO RETAIN
VENTING TO COLLARS
RECOMMENDED.
BLOWER ACCESS
COVER PLATE
23015-3-0707