Download Print this page
Lightolier 1004ICX Installation

Lightolier 1004ICX Installation

High wattage insulated ceiling frame-in kits

Advertisement

Quick Links

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTALLATION PROCEDURE FOR HIGH WATTAGE INSULATED CEILING
FRAME-IN KITS 1004ICX, 1004ICXN, 1104ICX, 1104ICXN,
NOTE: I.C. Frame-In Kit may be used in direct contact with insulation.
Fig. A
Frame-In
WARNING: USE ONLY WITH LIGHTOLIER REFLECTOR TRIMS MARKED WITH I.C. LAMPING INFORMATION. USE OF OTHER
MANUFACTURERS' TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD
1. FRAME-IN (Fig. A)
Locate fixture along joist and line up bottom edge of HINGED
MOUNTING BAR with the bottom of joist and fasten in place.
Note: Integral nail version available
FOR JOIST SPACING LESS THAN 16" ON CENTER (TO 12" ON CENTER):
• MOUNTING BAR CHANNELS can be shortened and used as
nailing legs in tight spaces. Simply remove INNER BAR from
holed CHANNEL, bend CHANNEL at appropriate point and
use extra screw to secure it to the joist. (Fig. G)
NEW CONSTRUCTION
Fig. B
Fig. C
Wire-In
Swing-Up
5
1
/
" 1004ICX
4
5
5
/
" 1104ICX
8
CENTER LINE OF
APERTURE OPENING
6
3
/
" 1004ICX
8
6"
1104ICX
HINGED MOUNTING BAR
Fig. D
Close-In
BEND AT HOLE
For suspended ceilings:
• Rotate HINGED BAR ENDS to position shown
and fully extend bars.
• Crimp bottom of edge of CHANNEL to prevent
rotation of HINGED BAR ENDS.
• Bend NON-HINGED end of mounting bar at
featured hole location and extend out.
• Position notched area of MOUNTING BARS onto
T-BAR and lock by bending TAB underneath
T-BAR BEAD as shown.
• For suspended ceiling, make certain that bottom
of Mounting Frame is no higher than 1" above
ceiling line.
HINGED BAR ENDS
CHANNEL
LIGHTOLIER a GENLYTE THOMAS company.
®
631 Airport Road, Fall River, MA 02720
INSTRUCTION SHEET NO.
IS:1104ICX
B1204 Page 1 of 2
Fig. E
Fig. F
Snap-On
Push-Up
TAB
BEND AT TAB
T-BAR
TAB
Fig. G

Advertisement

loading

Summary of Contents for Lightolier 1004ICX

  • Page 1 Close-In Snap-On Push-Up Frame-In WARNING: USE ONLY WITH LIGHTOLIER REFLECTOR TRIMS MARKED WITH I.C. LAMPING INFORMATION. USE OF OTHER MANUFACTURERS’ TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD 1. FRAME-IN (Fig. A) BEND AT HOLE Locate fixture along joist and line up bottom edge of HINGED MOUNTING BAR with the bottom of joist and fasten in place.
  • Page 2 SEE SEPARATE fully engage into SLOTS in REFLECTOR. REFLECTOR TRIM INSTRUCTION 7. PUSH-UP (Fig. F) SHEETS Push REFLECTOR TRIM straight up until it is tight against ceiling. ® LIGHTOLIER a GENLYTE THOMAS company. 631 Airport Road, Fall River, MA 02720...

This manual is also suitable for:

1004icxn1104icx1104icxn