Quick Links

READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY
INSTRUCTION SHEETS BEFORE INSTALLING ANY TRACK ITEM.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal
code specifications. To assure full compliance with codes and regulations, check with your local electrical
inspector before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
Caution:
• Turn off power at fuse box before installing track.
• Instructions for grounding must be followed. Failure to do
so may result in a hazardous condition.
• Use only #12 ga. solid copper wire in connectors to
maintain proper track rating.
• Do not supply Advent Track from two separate 120V branch
circuits as this could overload the neutral track conductor
leading to an electrical safety hazard.
• Observe polarity, white (neutral) wire must be connected
to terminal marked "NEUT". Failure to observe Polarity may
result in an electrical hazard.
Stem mounting kits (18" or 48" long) may be attached to the track at
any point and may be spaced up to 4' apart. They may be used to feed
power into the track. The unthreaded end of a stem may be field cut
using a hacksaw or a similar cutting device. The Stem Extension Kits
(48") is used to lengthen a stem 48". The Stem Extension Kit cannot
be field cut.
Instructions show the Stem Mounting Kit being installed on Basic
Track, providing power feed to a Live End. The same instructions
apply to power feed to an Advent Live End, Basic, Advent, ProSpec In-
Line, "L", "T", "X" or Variable Angle connector and ProSpec Feed Track.
For Basic "X" and "T" connectors, the neutral terminal is the lower
terminal which lines up with the bead in the track, see Instruction
Sheet IS:6165.
A. MOUNTING STEMS TO CEILING
1. Power feed Stem must be stem adjacent to fees in point of track.
(Wires cannot pass beneath two stems).
2. Splice Supply Leads, #12 AWG solid TW wire (not included), to
branch circuit leads in Outlet Box: white to white, black to black
(red to red in Advent). Supply Leads must be long enough to run
horizontally along the track to the track feed-in point. Pass Supply
Leads through Stem Mounting Plate and connect #12 AWG
Ground Wire to Ground Screw on the Stem Mounting Plate.
3. Fasten Stem Mounting Plate to Outlet Box. Mount other Stem
Mounting Plate(s) to ceiling in a straight line. Space not more than
4' apart. See Fig. 1.
4. Assemble Track Clamps as shown in Fig. 1. Screw Track Clamps
onto Stems and slip Screw Collars and Canopies onto Stems.
5. Pass Supply Leads through Stem used for power feed, insert
Stems into Stem Mounting Plates and tighten Set Screws. Thread
Screw Collars onto Stem Mounting Plates. See (Fig. 1 and 2).
Installation Instructions for Stem Mounting Kit
for use with Lytespan and ProSpec
IS:7586
Track Systems Only.
Outlet Box
Ground Wire
Ground Screw
Groung Spring
Canopy
Screw Collar
Supply Leads
Fig. 1
Center Barrier
Broken Off
Wireway Cover
Live End
Supply
Leads
Screw
Bottom Cover
Fig. 2
FALL RIVER, MASSACHUSETTS 02720
MONTREAL, QUEBEC, CANADA
INSTRUCTION SHEET NO.
B1197
Page 1 of 2
Stem Mounting Plater
Set Screws
Stem
Screws
Track Clamps
Stem
Screw
Track Clamp
Track Unit
Track Rib
Bead
© 1997

Advertisement

loading

Summary of Contents for Lightolier Stem Mounting Kit

  • Page 1 READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY INSTRUCTION SHEET NO. INSTRUCTION SHEETS BEFORE INSTALLING ANY TRACK ITEM. IS:7586 This fixture is intended for installation in accordance with the National Electrical Code and local or Federal code specifications. To assure full compliance with codes and regulations, check with your local electrical inspector before installation.
  • Page 2 INSTRUCTION SHEET NO. Installation Instructions for Stem Mounting Kit IS:7586 ™ for use with Lytespan and ProSpec Track Systems Only. B1197 Page 2 of 2 B. MOUNTING TRACK ONTO STEMS Center Barrier Track Rib 1. Loosen Screws on Track Clamps. In the stem used for power feed, Wireway Cover the Track Clamps must be positioned as shown in Fig.