5. Pneumatic Connection

10
ATTENTION !
For a fault-free functioning of the pneumatic control sequences, the
following notes are to be observed.
The compressed air supply must be so conceived that even at the
moment of the greatest air consumption a minimum operating pressure
of 5 bar is not fallen short of.
The connection to the compressed air supply is made with the
accessories available as optional equipment ( 0797 003031 ) or with
in-house connection material.
Operating pressure 2 = 6 bar
The blower pressure 1 must be suitable for the material.
Standard setting: approx. 3 bar
To set the pressure, lift and turn the appropriate knob.
Turn to the left
Turn to the right
= Decrease pressure
= Increase pressure
1
2