CONTROLS
KEYPAD
SWITCH S1
GATE OPEN TO Selects the direction the gate will open (LEFT/RIGHT).
LEFT/RIGHT
SWITCH S2
POWER FAIL
LEFT/RIGHT
INDICATORS
LED indicators light when controls and inputs are active. Additional indicators are as follows:
DISPLAY
LEFT LIMIT
RIGHT LIMIT
BATTERY
UPS OPEN
XMIT
RECV
LINE
OFF HOOK
FAULT
MAX RUN TIME
REVERSE
OVERLOAD
OPEN MTR
MTR LEFT
MTR RIGHT
Rev C
The 12-key keypad is used for local operation, programming and service.
Selects the direction the Power Fail Operation option will move the gate
(LEFT/RIGHT) if AC power fails.
This is a seven segment character display that gives numerical response
to service personnel during programming and operation.
Indicates that the LEFT limit switch is activated.
Indicates that the RIGHT limit switch is activated.
When optional UPS is installed, this indicates that AC power has been
lost and the system is operating on the battery. Not available yet.
When optional UPS is installed, this indicates the battery has only enough
energy left for one more gate motion, and moves the gate to a full open or
full closed position as programmed in the "Power Fail Position". Not
available yet.
Indicates data is being sent to the other unit in a Master/Slave system.
Indicates data is being received from the other unit in a Master/ Slave
system.
Indicates the ring detect for an incoming telephone call. It also indicates if
the phone line is available when the gate operator wants to initiate a call.
Indicates the gate operator is off hook and using the phone line.
Indicates a fault or alarm condition. See Fault List.
Indicates the motor ran for more than 75 seconds without reaching a limit
switch, and was stopped. Usually requires mechanical service. See
Fault List.
Indicates the peak motor current threshold was reached and the motor
was stopped. See Fault List.
Indicates the average motor current threshold was reached and the motor
was stopped. See Fault List.
Indicates the motor is engaged, but is not drawing any current. The
thermal overload switch on the motor may need to be reset. See Fault
List.
Indicates the gate is moving to the left.
Indicates the gate is moving to the right.