INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of the door at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, and away from moving parts of the door and door
hardware. The installation surface must be smooth and
fl at. If installing into drywall, drill 5/32" holes and use
anchors provided. For pre-wired installations (as in new
home construction), it may be mounted to a single gang
box (Figure 1).
NOTE: After installation, a green indicator light behind
the cover will indicate proper connection. If not lit, the
Lock and Light features will not function (reverse wires to
correct).
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back
of door control by color: white wire to 2 and white/red
wire to the 1 (Figure 2).
2. Remove the cover by gently prying at slot in top of
cover with a small fl at head screwdriver (Figure 3).
Fasten with 6ABx1-1/4" self-tapping screws (drywall
installation) or 6-32x1" machine screws (into gang
box) as follows:
• Drill and install bottom screw, allowing 1/8" (3 mm)
to protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fi t.
• Install top screw with care to avoid cracking plastic
housing. DO NOT overtighten.
NOTE: The push bar may stick if the door control is not
mounted on a smooth surface. If a click is not heard when
pressing the push bar, loosen the two mounting screws or
relocate the door control to a smoother surface.
3. (Standard installation only) Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to
secure wire in several places. DO NOT pierce wire with
a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red (Figure 4).
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
5. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.
NOTE: DO NOT connect the power and operate the opener
at this time. The trolley will travel to the full open position
but will not return to the close position until the sensor
beam is connected and properly aligned. See Safety
Reversing Sensor Instructions beginning on page 19.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing
door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out
of reach of children at a minimum height of 5 feet
(1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to
door travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of
closing garage door.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/4"
(standard installation)
Screw 6-32x1"
(pre-wired)
Figure 1
PRE-WIRED
INSTALLATION
24 Volt
Bell Wire
To Replace
Insert Top
Tabs First
Push Bar
Detector Switch
Cover
Figure 3
To Replace
Insert Top
Tabs First
Push Bar Cover
Figure 4
Door Control Connections
16
Insulated
Staples
Drywall Anchors
Figure 2
Bell Wire
Top Mounting
Hole
Door
Control
Terminal
Screws
ON
Bottom
OFF
Mounting
Hole
(BACK VIEW)
Detector Switch
ON
OFF
To release or
insert wire,
push in tab with
screwdriver tip
Red White Grey
Strip wire 7/16" (11 mm)
24 Volt