18. MIDI Implementation ADI-8 QS

18.1 Basic SysEx Format

Value
F0h
00h 20h 0Dh
41h
00h..7Eh, 7Fh
mm
nn
oo
F7h
Bank Number / Device ID
The lower nibble refers to the device ID (0..7), the higher nibble refers to the bank number
(0..7), e. g. 25h means bank 2, device 5. 7Fh addresses all banks and all devices.

18.2 Message Types

Value
10h
11h
20h
30h
31h
Request Value
Format: F0 00 20 0D 41 (bank no. / dev ID) 10 F7
This string triggers a complete dump of all value response data bytes.
Request Level meter Data
Format: F0 00 20 0D 41 (Bank no. / dev ID) 11 F7
This string triggers a shorter dump of only the level meter data.
Set Value
Sets any number of parameters.
nn / oo can be repeated freely.
Value Response
After being triggered by receiving a request value command, device sends a string of all value
response data bytes. Message type is set to 30h.
Level Meter Response
After being triggered by receiving a request level meter data command, device sends a string of
all level meter data bytes. Message type is set to 31h.
Level meter Data Response Format
F0 00 20 0D 41 (bank no. / dev ID) 31 (AD ch.1) (ch.2) (ch.3) (ch.4) (ch.5) (ch.6) (ch.7) (ch.8)
(DA ch.1) (ch.2) (ch.3) (ch.4) (ch.5) (ch.6) (ch.7) (ch.8) F7
The peak level value will be stored and transmitted with the next level meter data request,
and the stored value will be reset.
Name
SysEx header
MIDITEMP manufacturer ID
Model ID (ADI-8 QS)
Bank number / device ID (7Fh = broadcast, all IDs)
Message type
Parameter number (see table 1)
Data byte
EOX
Name
Request value
Request level meter data
Set value
Value response
Level meter data response
User's Guide ADI-8 QS © RME