Diagnostic Error Code
086-199-XXX Mouse Port interface test failed, cause
unknown
089-000-XXX Microprocessor Test Passed
089-XXX-XXX Microprocessor failure
089-195-XXX Microprocessor Test aborted by user
089-196-XXX Microprocessor test halt, error threshold
exceeded
089-197-XXX Microprocessor test warning
089-198-XXX Microprocessor test aborted
089-199-XXX Microprocessor test failed, cause unknown
170-000-XXX Voltage Sensor(s) Test Passed
170-0XX-XXX Voltage Sensor(s) failure
170-195-XXX Voltage Sensor(s) Test aborted by user
170-196-XXX Voltage Sensor(s) test halt, error threshold
exceeded
170-197-XXX Voltage Sensor(s) test warning
170-198-XXX Voltage Sensor(s) test aborted
76
ThinkCentre Hardware Maintenance Manual
FRU/Action
1. See "Undetermined problems" on page 82.
2. Flash the system and re-test. See "Flash update
procedures" on page 217.
3. Replace component under function test.
No action
1. Microprocessor(s)
2. System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. Flash the system. See "Flash update procedures"
on page 217.
2. Go to "Undetermined problems" on page 82.
1. See "Undetermined problems" on page 82.
2. Flash the system and re-test. See "Flash update
procedures" on page 217.
3. Replace component under function test.
No action
1. Flash system
2. System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Flash the system and re-test. See "Flash update
procedures" on page 217.
3. Go to "Undetermined problems" on page 82.