Packaged air--handling units, 60 hz with puronr (r-410a) refrigerant sizes: 16, 25, 28, 30

Advertisement

Quick Links

524J
PACKAGED AIR- -HANDLING UNITS, 60 Hz
WITH PURON
R
(R- - 410A) REFRIGERANT
SIZES: 16, 25, 28, 30
NOTE: Read the entire instruction manual before starting the installation
This supplement only applies to 524J size 16, 25, 28 & 30 units when the 13
is either a 1, 2, or 3 as shown in the Model Number Nomenclature diagram below. Check the Unit
Nameplate (see Figs. 1 & 2). If the digit in the 13
Model
524J = Packaged Air-Handling Unit
®
Puron
R-410A Refirgerant
Voltage
T = 575-3-60l
J = 208/230-1-60
P = 208/230-3-60
E = 208/230/460-3-60*
Cooling Tons
16 = 15 ton
25 = 20 ton
28 = 25 ton
30 = 30 ton
Type of Coil
A = Standard 4 Row DX Puron Coil
H = Heat Pump
* Size 16 units are triple voltage in the "E" configuration unless
the unit is equipped with the discrete 460-3-60 High Static motor option.
** Size 30 units - designate standard motor and high static drive.
Electrical Data Supplement

MODEL NUMBER NOMENCLATURE

1
2
3
4
5
6
5
2
4
J
E
1
th
position is not either a 1, 2, or 3 discard this document.
7
8
9 10 11 12 13 14 15 16 17
1
6
A
0
0
0
A
Coil Options
A = Standard Aluminum Fin / Copper Tube
Factory Assigned
0 = Default
Factory Assigned
0 = Default
Factory Assigned
0 = Default
th
digit of the Model Number
0
A
A
A
Indoor Fan Options – Belt Drive
1 = Standard Motor/ Standard Drive
2 = Standard Motor / Medimum Drive
3 = High Motor / High Drive**
C11002

Advertisement

loading

Summary of Contents for Bryant 524J

  • Page 1: Model Number Nomenclature

    524J PACKAGED AIR- -HANDLING UNITS, 60 Hz WITH PURON (R- - 410A) REFRIGERANT SIZES: 16, 25, 28, 30 Electrical Data Supplement NOTE: Read the entire instruction manual before starting the installation This supplement only applies to 524J size 16, 25, 28 & 30 units when the 13 digit of the Model Number is either a 1, 2, or 3 as shown in the Model Number Nomenclature diagram below.
  • Page 2: Safety Considerations

    Consult local building codes and appropriate national electrical codes (in USA, ANSI/NFPA70, National Electrical Code (NEC); in Canada, CSA C22.1) for special requirements. MODEL BRYANT SERIAL Compressors (Factory Charged) Refrigerant/System Test Pressure Gage...
  • Page 3 MODEL BRYANT 524JE16A000A10AAA SERIAL Compressors (Factory Charged) Refrigerant/System Test Pressure Gage Volts AC PH Hz RLA R — PSI ( kPa) Fan Motors Volts AC PH Hz Power Supply Volts AC Volts Volts MCA * MOCP * * MCA = Min Circuit Amps (Fuse or HACR Bkr.)
  • Page 4 IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately. Catalog No: SS524J---01 2011 Bryant Heating and Cooling Systems. D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/11 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.