9.2.1.1. Country Display
The country display displays the country specifications as designated by the solder
points (1 ~ 3.)
[UK, GER, FRE, BEL, USA/CAN/AUS]
ROM
Specification
US
UK
GER
9.2.1.2. Head Rank Display
The head rank displays the rank as designated by the solder points (A ~ C).
The rank "B" is defined as the setting for no soldering.
Country Specification
B
A
C
9.2.1.3. Power Supply Voltage Check Display (Inspection voltage: 7.5 ± 0.2 V)
Displays "
" when within the required input voltage range.
Displays " X " when out of the range.
MODEL
PT-1100/1130/1170
/1180/11Q/ST-1150
PT-1250/1160
PT-1250
LCD Display
0
B
A
C
Country
Voltage Display
Specification
US
0
Head Rank
Fig. 3 An Example of INFO Mode Display
II-
28
Country
Specification
Display
USA/CAN/AUS
CANADA
UK
French
Belgium
German
("L" indicates the soldering.)
Solder Points
A
B
H
H
H
L
L
H
H
H
("L" indicates the soldering.)
Country Display: USA/CAN/AUS
Head Rank Display: B rank
Voltage Display: No problem
Solder
LCD
Points
1
2
3
US
H
H
H
CA
L
H
H
UK
H
H
H
FR
L
H
H
BE
H
L
H
GE
H
H
H
C
H
H
H
L