Bradford White EverHot TGHE-160I-NX Installation And Operation Instruction Manual page 40

Condensing tankless gas water heater
Table of Contents

Advertisement

Mounting the Vent System – Vertical Discharge
Figure 32. Illustration Showing the Installation of Vertical Discharge Venting.
Vent connections must be firmly pressed together, so that the gaskets form an airtight seal. Secure the
system with a vent pipe clamp or perforated hanger iron.
High Altitude Installations
The default setting for the water is 0-2,000 ft (0-610 m) with dip switch numbers 2 and 3 in the OFF
position. If this water heater is installed at a higher altitude, it is necessary to modify the dip switch
settings according to Table 9.
Switch No. 2
Switch No. 3
Table 9. Dip Switch Settings for High Altitude Installations.
0-2000 ft
2001-5200 ft
(0-610 m)
(610-1585 m)
OFF
OFF
Switch No.
Switch No.
ON
O
O
1
F
F
2
F
F
3
4
5
6
7
8
5201-7700 ft
(1585-2347 m)
OFF
ON
ON
OFF
Switch No.
ON
O
1
F
2
F
3
4
5
6
7
8
40
7701-10200 ft
(2347-3109 m)
ON
ON
Switch No.
ON
ON
O
1
F
2
F
3
4
5
6
7
8
1
2
3
4
5
6
7
8