INSPECTION
Perform
the tests below
to ensure
proper
operation
of the GFCI.
Record your test on the GFCI test card provided
on the generator.
Before each use:
If the generator
is stored outdoors,
unprotected
from the weather, test
the GFCI receptacle
before
each use as described
in the monthly
inspection.
Monthly:
Under normal operating
conditions,
perform the GFCI test monthly.
1. Unplug all appliances
from the generator.
2. Start the engine.
3. Turn the circuit breaker ON.
4. Press the TEST BUTTON
-The
RESET BUTTON shouldextend
with a click.
-If
the RESET BUTTON
does not extend,
contact
an authorized
Honda generator
dealer.
RESET BUTTON