10.

SAFETY DEVICES

Circuit protection
Fan motor
protection
High Pressure
Protection
Compressor
protection
Protection form
Current fuse
(NEAR THE TERMINAL)
Current fuse
(MAIN PRINTED
CIRCUIT BOARD)
Thermal protection
program
Pressure Switch
Thermal protection program
(DISCHARGE TEMP.)
Thermal protection program
(DISCHARGE TEMP.)
Model
AOÜR24LC
20A 250V
5A 250V
15A 250V
3.15A 250V
+15
OFF :100
°C
-10
+15
ON : 105
°C
-10
-
-
OFF : 110°C
ON : After 7 minutes
- (02 - 19) -
AOÜR30LC, AOÜR30LF
20A 250V
5A 250V
15A 250V
3.15A 250V
OFF : 130±20°C
ON : 100±20°C
OFF : 4.2±0.1MPa
ON : 3.2±0.15MPa
OFF : 110°C
ON : After 40 minutes
OFF:110°C
ON: After 7 minutes