Servicing The Boiler - Baxi Combi 80Eco Installation And Servicing Instructions

Gas fired wall mounted combination boiler
Hide thumbs Also See for Combi 80Eco:
Table of Contents

Advertisement

11.0 Servicing the Boiler

Case Front Panel
11 .1
Annual Servicing
1. For reasons of safety and economy, it is
recommended that the boiler is serviced annually.
Servicing must be performed by a competent
person.
2. After servicing, complete the relevant section
of the "Benchmark" Installation, Commissioning
and Service Record Log Book. This should be in
the possession of the user.
3. Ensure that the boiler is cool.
4. Ensure that both the gas and electrical
Fig. 47
supplies to the boiler are isolated.
5. Slacken the screws securing the facia panel.
Lift the outercase panel so that its securing tabs
are clear of the facia. Remove the panel (Fig. 47).
Facia Panel
6. Remove the screws securing the inner door
panel. Lift the panel slightly to disengage it from
the studs on top of the case (Fig. 48).
7. Note the positions of the two sensing tubes on
the outlet elbow and three wires on the fan motor
and remove them (Fig. 49).
Combustion
Box Door
8. Slacken the screws on the outlet sealing collar.
Inner Door
Ease the collar upwards as far as possible
Panel
(Fig. 50).
9. Remove the four screws securing the
combustion box door and remove the door
(Fig. 48).
Fig. 48
Fan Wires
Fan
Sensing Tubes
Outlet Sealing
Fig. 49
Collar
Fig. 50
25