Data Collection - iRobot Roomba 570 Service Manual

Roomba 500 series
Hide thumbs Also See for Roomba 570:
Table of Contents

Advertisement

2.
The robot CANNOT be powered off and will not respond to any buttons until the
BATTERY IS REMOVED (do not do this unless the procedure calls for it).

DATA COLLECTION

In both manual and automatic advance modes, data can be collected by connecting a serial cable under
the face plate to the computer. {Note : if using HyperTerminal, then select 115200 Bits and 'none' for
Flow Control.}
Cable connected during test : When executing the BIT in automatic mode, when the last step is
completed, the Roomba will transmit a summary of the test results. If the operator presses the CLEAN
button again, the Roomba will transmit the summary again.
Cable connected after test : This allows the BIT to be completed without being encumbered by a serial
cable. When the test is completed, pass or fail, the cable can be connected and the data downloaded
by pressing CLEAN.
Example output :
SUMMARY: START
SUMMARY: DATE-TAG 2007-06-20-0411-L
SUMMARY: BOOTLOADER-ID 0000 01BB
SUMMARY: BOARD-ASSEMBLY 3.4
SUMMARY: BOARD-REVISION 0
SUMMARY: FACTORY-TEST PASS
SUMMARY: flash version: 2
SUMMARY: flash info crc passed: 1
SUMMARY: (user-button-day?) disabled
SUMMARY: (user-button-hour?) disabled
SUMMARY: (user-button-minute?) disabled
SUMMARY: (user-button-scheduling?) disabled
SUMMARY: (user-button-clock?) disabled
SUMMARY: (bump-left?) PASS
SUMMARY: (bump-right?) PASS
SUMMARY: (cliff-left?) PASS
SUMMARY: (cliff-right?) PASS
SUMMARY: (cliff-front-left?) PASS
SUMMARY: (cliff-front-right?) PASS
SUMMARY: (and (lt-bumper-left?) (not (bump?))) PASS
SUMMARY: (and (lt-bumper-right?) (not (bump?))) PASS
SUMMARY: (and (lt-bumper-front-left?) (not (bump?))) PASS
SUMMARY: (and (lt-bumper-front-right?) (not (bump?))) PASS
SUMMARY: (and (lt-bumper-center-left?) (not (bump?))) PASS
SUMMARY: (and (lt-bumper-center-right?) (not (bump?))) P
SUMMARY: (wheel-drop-left?) PASS
SUMMARY: (wheel-drop-right?) PASS
SUMMARY: (rcon?) PASS
SUMMARY: (valid-code-in-channel? dir-left) PASS
SUMMARY: (valid-code-in-channel? dir-right) PASS
SUMMARY: (battery-voltage-ok?) PASS
SUMMARY: (battery-temperature-ok?) PASS
SUMMARY: (baseline-current-ok?) PASS mA -242 min -300 max -14 mV 16059 degrees-C 37
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents