Applied Operations; Alarm Operation - JVC RMP-2580U - Remote Controller For Color Domes Instructions Manual

Remote control unit
Hide thumbs Also See for RMP-2580U - Remote Controller For Color Domes:
Table of Contents

Advertisement

3. APPLIED OPERATIONS

ALARM OPERATION

Alarm input signals can be applied to the DATA I/O terminals on the rear panel. The unit functions in either the
ALARM PRIORITY mode or the MANUAL PRIORITY mode when an alarm signal is input. ( REF. : "CONTROL
UNIT SCREEN" on page 28 and "PRIORITY item of ALARM SCREEN" on page 32.)
CAMERA
CAMERA
SETUP
POWER
ALARM
MENU
MENU
SET
KEY LOCK
LENS
LENS
1
SPEED
4
IRIS
IRIS
CLOSE
OPEN
OPEN
FOCUS
FOCUS
7
NEAR
NEAR
FAR
AF
AF
ZOOM
ZOOM
TELE
CLEAR
WIDE
WIDE
Alarm Operation Modes
When an alarm signal is received, this unit performs the following operations.
<Alarm priority mode>
The video is switched to the camera position from which the alarm signal is received.
An alarm signal will automatically override and cancel the operation of either AUTO PATROL or AUTO SEQUENCE. (AUTO
SEQUENCE: In A mode only.)
The preset alarm title is displayed in the preset size.
The ALARM indicator blinks and the buzzer sounds. ( REF. : "BUZZER TIME" on page 32 for the setting method.)
The CAMERA display indicates the number ID of the camera which has given the alarm signal.
The UNIT ALARM output is turned ON.
<Manual priority mode>
When an alarm signal is received during manual operation (except during the AUTO PAN, AUTO PATROL and AUTO SE-
QUENCE operations), the alarm operation does not start.
When an alarm signal is received from a camera other than the camera being controlled manually, the alarm operation starts
but, unlike in the alarm priority mode, the buzzer does not sound and the camera in question is not automatically selected.
<Example when Alarm 1 and Alarm 2 are input during AUTO SEQUENCE in the A Mode>
Alarm input 1
Alarm input 2
Camera 1 alarm time
Camera 2 alarm time
UNIT ALARM
output duration
MONITOR OUTPUT 1
Set in item "TIME" in the AUTO SEQUENCE screen.
CAMERA2 CAMERA3
MONITOR OUTPUT 2
Time period of switching by CAMERA SW.
• In B mode, the MONITOR OUTPUT 2 connector outputs the same video as the MONITOR OUTPUT 1 connector.
For B Mode connection. REF. : [Applied System (B Mode)] on page 21.
B Mode output signal REF. : [B Mode] on page 22.
• While the MENU screen is displayed, the alarm signal is not accepted.
RM-P2580
RM-P2580
REMOTE CONTROL UNIT
REMOTE CONTROL UNIT
POSITION
POSITION
AUTO
AUTO
F-1
F-2
F-3
F-3
CAMERA/POSITION
CAMERA/POSITION
PAN/TILT
PAN/TILT
2
3
CAMERA
CAMERA
POSI-
POSI-
TION
5
6
OPTION
OPTION
OPTION
OPTION
1
2
8
9
AUTO
AUTO
AUTO
AUTO
PAN
PAN
PATROL
PATROL
0
ENTER
/HOME
/HOME
Alarm input 1
ALARM TIME
CAMERA3
CAMERA
CAMERA4
CAMERA
TO CAMERA
TO CAMERA
RX+ RX- TX+ TX-
POWER
OFF
ON
`
AC
INPUT
1 2
3
4
5 6
7
ON
Alarm input 2
ALARM TIME
CAMERA
CAMERA
*Encircled number shows the alarm condition.
DATA I/O terminals
DATA I / O
DATA I / O
UNIT
UNIT
CAMERA
CAMERA
SERIAL-1
SERIAL-1
COM
COM
1
2
3
4
5
6
7
8
COM 9/1
COM
9/1 10/2
10/2 11/3
11/3 12/4
12/4 13/5
13/5 14/6
14/6 15/7
15/7 16/8
16/8 COM
COM
AUTO
AUTO
ALARM
ALARM
COM
COM
SW
SW
COM
COM
VIDEO INPUT
VIDEO INPUT
1
2
3
4
5
6
7
8
MONITOR
MONITOR
OUTPUT
OUTPUT
8
1
2
3
4
5
6
7
8
VIDEO OUTPUT
CAMERA2
CAMERA4 CAMERA5 CAMERA6 CAMERA7
SERIAL-2
SERIAL-2
MONITOR
MONITOR
OUTPUT
OUTPUT
1
2
CAMERA3
Time
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm-p2580

Table of Contents