Temp Control &Operation Functions
11-1) DISPLAY DESIGN
11-2) Temp Control Function
1) Freezer Temperature Control
※ When the Freezer button is pressed,the current set temp will be displayed.And, when the button is pressed
again within 5 seconds,it will carry out the following 1-2)and when there is no button press,it will go back to
the previous display.
1-1) The temperature will be selected between 8 ℉ and -14 ℉ at an interval of 2 ℉ by pressing one button.
1-2) The temperature will be selected in the following order.
(-2 ℉→-4 ℉→-6 ℉→-8 ℉→-10 ℉→-12 ℉→-14 ℉→8 ℉→6 ℉→4 ℉→2 ℉→0 ℉)
1-3) When power is on or there is a power failure,it will display the real temperature.
(It displays the real temperature when a function button is pressed)
1-4) The STD temperature for each step is as follows.(Based on 1/3H copper bar)
Step
1
Temp
8℉
1-5) When the Freezer button is pressed,7-SEG will be changed immediately.But, its function will go into
operation in 10 seconds.
2
3
4
6℉
4℉
2℉
0℉
5
6
7
8
-2℉
-4℉
-6℉
26
9
10
11
-8℉
-10℉
-12℉
-14℉
12