Connecting A Pump Start Relay; Connecting The Transformer - Toro 53765 - Outdoor Ecxtra Sprinkler Timer User Manual

Automatic sprinkler system control timer
Table of Contents

Advertisement

Connecting a Pump Start Relay

CAUTION: To prevent timer damage, ensure the
24 V ac pump relay current draw does not exceed
0.30 Amps. Do not connect the timer directly to the
pump starter.
1. Route a wire pair from the pump relay into the timer
housing.
2. Connect one wire to the terminal labeled COM (8).
Connect the remaining wire to the terminal labeled
PUMP/MV (9) as shown below.
12
SENSOR
24 VAC
PUMP/MV
COM
13
24 V a.c.
Pump Relay
CAUTION: To prevent pump damage due to
"dead-heading," connect a jumper wire from any
unused zone terminal to a zone terminal with a valve
connected.
Note: Refer to "Pump Control" section on page 29 for
important pump control information.
8
Jumper Wire
Valve Common Wire
Connecting the Plug-In Transformer
CAUTION: Do not plug the transformer into an
electrical outlet until all of the wiring procedures
have been completed.
1. Route the cord from the transformer (13) through the
small opening provided in the base of the housing as
shown below.
13
2. Connect one transformer cable wire to each terminal
labeled 24 VAC (10). The wires can be connected to
either terminal.
Note: The display will begin flashing 12:00
button to stop the display from flashing.
10
SENSOR
24 VAC
. Press any
AM
ST

Hide quick links: