Electric
Supply voltage:
534186 (WT105BL208)
534187 (WT105BR208)
534188 (WT105BL240)
534189 (WT105BR240)
Dishwasher requires two separate electrical service connections.
Connection 1 for RINSE MODULE; Connection 2 for PREWASH AND
WASH MODULE. Refer to below table for Amp requirements.
Connection 1:
208 V/3ph/60Hz
240 V/3ph/60Hz
Connection 2:
208 V/3ph/60Hz
240V/3ph/60Hz
Total Amp Load:
208 V/3ph/60Hz
240 V/3ph/60Hz
Exhaust Requirements
Unit supplied as standard with extended vent hoods
(can be removed during installation if not required).
Exhaust extraction not more than 177 CFM (300m³/h)
Refer to installation diagram for minimum exhaust hood
installation height .
Key Information
Productivity racks per hour
(max speed):
Productivity racks per hour
(min speed):
Table to Table connection:
Number of Tanks:
Height with door open:
Charging hole size (width):
Charging hole size (height):
Shipping weight:
Shipping width:
Shipping depth:
Shipping height:
Shipping volume:
Noise level:
Unit predisposed to accept external detergent dispensers, detergent
probes and rinse aid dispensers.
Warewashing
105" " " " " Multi Tank Conveyor Dishwasher WT105
208 V/3ph/60Hz
208 V/3ph/60Hz
240 V/3ph/60Hz
240 V/3ph/60Hz
71A
62A
69A
62A
136.1A (44.4 kW)
121.1A (44.4 kW)
350 racks / 6300 dishes
(average 18 dishes per rack)
250 racks / 4500 dishes
(average 18 dishes per rack)
106-1/4" (2698 mm)
3
83-7/16" (2119 mm)
20-7/8" (530 mm)
19-3/4" (501 mm)
1327 lb (602 kg)
129-15/16" (3300 mm)
40-15/16" (1040 mm)
81-1/8" (2060 mm)
148 cu.ft (4.18
3
)
<70 dBA
105" Multi Tank Conveyor Dishwasher
Water
Inlet Water supply pressure:
Inlet Cold Water Supply Temperature
for pre wash section:
Inlet Hot Water Supply Temperature
for wash and rinse section:
Inlet Water supply hardness:
Incoming Cold Water line size
(pre wash):
Incoming Hot Water line size
(wash and rinse section):
Drain line size (pre wash section):
Drain line size (wash section):
Drain line size (rinse section):
Hot Water consumption: Gallons/hr:
Water consumption/rack:
Pre wash Temperature:
Pre wash tank size:
Pre wash pump power:
Pre Wash water flow:
Wash Temperature:
Wash tank size:
Wash pump power (top wash arms):
Wash pump power (lower wash arms): 1.5 hp (1.2 kW)
Power Rinse Temperature:
Power rinse tank size:
Rinse pump power:
Final Rinse Temperature:
Final Rinse water flow:
Hot water booster capacity:
Initial fill Hot Water requirements:
Initial fill Cold Water requirements:
Warewashing
WT105
22 – 102 psi (150 – 700 kPa)
39 – 59 °F (4 - 15 °C)
140 °F (60 °C)
4-8 gpg (7-14 °fH) max
G 3/4"
G 3/4"
G 1-1/2"
G 1-1/2"
G 1-1/2"
87 gal/hr (330 liters/hr)
0.3 gal/rack (0.75 l/rack)
< 105 °F (<40 °C)
11.8 gal (45 liters)
0.5 hp (0,37 kW)
39 gal/min (150 l/min)
160 – 172 °F (71-78 °C)
40 gal (150 liters)
3 hp (2.2 kW)
160 – 172 °F (71-78 °C)
6 gal (23 liters)
0.4 hp (0.32 kW)
180 – 194 °F (82-90 °C)
79 gal/min (300 l/min)
3 gal (11.3 liters)
40 gal (150 liters)
11.8 gal (45 liters)
10-29-08