HP ProLiant DL360p Reference Manual page 92

Configuring arrays on hp smart array controllers reference guide
Hide thumbs Also See for ProLiant DL360p:
Table of Contents

Advertisement

Error code Error message
Too many coinciding expansion, migration,
2053
or extension operations
Controller does not support license keys
2056
Invalid license key
2059
Controller does not support SSP
2064
Invalid Action
2817
Invalid Method
2818
Invalid Controller
2819
No controllers detected
2821
Invalid Rebuild Priority
2823
Invalid Expand Priority
2824
Invalid Array
2825
Array not specified
2826
New Array ID does not match the next
2827
available Array ID.
New Array ID already exists
2828
Cannot create Array
2829
Cannot expand Array
2830
Cannot change Array Spare
2831
Invalid physical drive
2832
Invalid Spare
2833
Invalid logical drive
2834
Comment or clarification
successfully.
The new configuration requires more
transformations than are possible at one time. For
example, you cannot expand a logical volume and
transform its RAID level at the same time.
The controller does not support license key entry or
deletion.
The entered license key is not a valid license key.
The controller does not support SSP functions.
The requested actions are invalid, for example,
combining -reset with capture mode.
The method must be either Custom or Auto.
An invalid controller value was specified.
No controllers were detected. This error applies to
Input mode only.
The specified rebuild priority is not supported.
The specified expand priority is not supported. This
error also occurs if the controller does not allow
expansion, and therefore does not support expand
priority.
The array ID is invalid.
The Array command is missing from the script file.
Some commands were found that require an Array
to be specified.
The array ID in the script file does not match the
array ID of the next available array. For example, if
the configuration has an Array A and the input file
specifies Array C (without Array B), then the script
generates this error.
The array ID specified in the script file (in Configure
mode) already exists in the configuration. Configure
mode can only create new arrays.
The controller will not allow a new array to be
created, either because the controller has no
unassigned physical drives attached or because the
maximum number of arrays or logical drives has
been reached already.
The Array could not be expanded, either because
the controller does not support expansion, or the
current configuration does not allow expansion to
occur on the array.
The spare state of the array could not be changed.
This error can occur when you attempt to add or
drop a spare and the current configuration does not
allow a spare state change for the array.
A specified physical drive is not a valid physical
drive, or it cannot be placed in the array.
A specified spare is not a valid spare drive, or it
cannot be placed in the array as a spare.
The logical drive ID is not valid.
HP Array Configuration Utility 92