Brother KE-436C Instruction Manual page 59

Electronic lockstitch pattern tacker with stepping foot and programming function
Hide thumbs Also See for KE-436C:
Table of Contents

Advertisement

11. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
Memory switches (00–0F)
Switch No.
When moving to the home position, the feed plate moves in the order
memo-00
position moves in the order r
(The feed plate does not move via the position that has been set by memo-3C.)
When moving to the home position, the feed plate moves in the order r
memo-01
position moves in the order
(The feed plate does not move via the position that has been set by memo-3C.)
memo-02
memo-03
Needle stops in up position during emergency stop. (Needle normally stops in down
memo-04
position.)
When sewing is finished, the feed plate moves via the machine home position to the start
memo-05
position.
memo-06
After the final stitch, the work clamp rises and then the feed plate returns to the start position.
memo-07
Intermittent work clamp is not used (does not rise).
When using an inner clamping device, the inner clamping device moves forward at the 1/4-
memo-08
way mark and returns at the 3/4-way mark for the pattern being sewn. (Inner clamping device
is available as an option.)
memo-09
Changes the wiper to air drive. (Air wiper is available as an option.)
memo-0A
Jog feeding becomes faster during programming.
memo-0b
ON when a two-stage tensioner is used (available as an option).
memo-0c
Clearing the emergency stop switch action is carried out using the STEP BACK switch.
memo-0d
Note: The factory default setting is ON, and it changes to ON when all memory settings are
Test feeding is carried out at the same speed as normal sewing. (For checking feed
memo-0E
operation)
After sewing is finished, the work clamp automatically opens and closes once. (practice
memo-0F
operation)
If memo-0E is ON, the work clamp opens and closes twice.
*1: The
direction is rotation with reference to the x axis, and the r direction is rotation with reference to the y axis.
Memory switches (10–1F)
Switch No.
memo-10
memo-11
Bobbin thread counter and production counter are adjusted when thread is trimmed.
memo-12
memo-13
memo-14
Needle up error detected.
When using the inner clamping device, shunting to prevent interference between the inner
memo-15
clamping device and the needle is not carried out after the sewing end. (Inner clamping
device is available as an option.)
memo-16
memo-17
memo-18
memo-19
memo-1A
memo-1b
memo-1c
Bobbin thread counter is decremented at the start of sewing.
When using an air pressure drop detection switch. (This detection switch is available by
memo-1d
special order.)
Changes the split number automatically by using an external switch. (Use option connector
memo-1E
P3 on the operation panel.)
Program number is changed automatically by using outside switch. (Use optional
memo-1F
connector P3 on the operation panel.)
53
r. (*1)
cleared.
Motion when set to ON
. (*1)
Motion when set to ON
KE-436C
Initial value
r and the start
and the start
ON
: OFF
Initial value
: OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents