Issue: When an enclosure has a status of OK, the enclosure health reason is displayed as "The enclosure
health is not known".
Workaround: The health reason field is only populated when the enclosure is in a degraded or fault status.
Issue: Following a reboot, the device mapper multipath may not detect all MPATH devices correctly.
Workaround: Issue the command multipath —v3 to recover missing devices.
Issue: In a Solaris iSCSI environment, path failover and failback functionality may not work correctly.
Workaround: Refer to SUN CR numbers 6764779 and 6844558.
Issue: Some entries in the SMU and CLI are not localized properly for all languages.
Workaround: HP is continually updating localized content.
Issue: Some configuration changes under heavy I/O may return a communication error.
Workaround: Retry configuration changes during a period of lower I/O.
Issue: Some cached data in the browser may not be updated while navigating through the SMU.
Workaround: Press CTR + F5 to refresh or log out and back into the SMU.
Issue: The tree view for a vdisk in SMU may not function properly.
Workaround: Click the ++ symbol at the top of the tree view. This refreshes the screen and enables the
tree view.
Issue: In single controller mode, some event log descriptions can indicate a second controller.
Workaround: These messages can be safely ignored.
Issue: During drive firmware upgrade, all volumes are taken offline to preserve data integrity.
Workaround: Plan drive firmware updates during a maintenance window.
Issue: In a c-Class blade environment, VMWare may fail I/O during failover operations.
Workaround: The VMWare kernel parameter ResetOnFailover must be set to 0 in order for array
failover to work properly.
Issue: SMU may display a flashing background or other display issues if left open for an extended amount
of time.
Workaround: Do not maintain an open SMU session for more than 24 hours. Log out of the SMU when
SMU tasks are complete.
Issue: SMU may lose authentication if the browser refresh button is clicked.
Workaround: Log back in to re-establish authentication.
Issue: In the SMU Enclosure Overview page, the column Serial Number is mislabeled; it should be labeled
WWID.
Workaround: This will be resolved in a future release.
Issue: The serial number for a volume returned by the SMU and CLI does not match the serial number returned
by VPD data.
Workaround: Serial numbers are shown in different formats. The last 16 digits of the serial number are
unique for each volume and match between the CLI, SMU, and VPD data.
Issue: You can not create volumes for OpenVMS using the Provisioning Wizard or Create Volume Set pages
of the SMU.
Workaround: Volumes for OpenVMS may only be created using the Create Volume page of the SMU.