Hardware Management Features; Fan Speed, Thermal, And Voltage Monitoring And Control; Chassis Intrusion - Intel DG43RK Product Manual

Desktop board
Hide thumbs Also See for DG43RK:
Table of Contents

Advertisement

Hardware Management Features

The hardware management features of Intel Desktop Board DG43RK enable the board
to be compatible with the Wired for Management (WfM) specification. The board has
several hardware management features including the following:
Fan speed monitoring and control
Thermal and voltage monitoring
Chassis intrusion detection
Fan Speed, Thermal, and Voltage Monitoring and
Control
Features of the board's fan speed, thermal, and voltage monitoring and control
subsystem include:
Monitoring of power supply voltages to detect levels above and below acceptable
values.
Smart fan control provided by the legacy I/O controller, delivering acoustically-
optimized thermal management. Fan speed controllers and sensors are integrated
into the legacy I/O controller.
Thermally monitored closed-loop fan control, for all onboard fans, that can adjust
fan speed according to thermal conditions.
Two thermal sensors (processor and a remote thermal sensor).

Chassis Intrusion

The board supports a chassis security feature that detects if the chassis cover has
been removed. The security feature uses a mechanical switch on the chassis that can
be connected to the chassis intrusion header on the Desktop Board. See Figure 22 for
the location of the chassis intrusion header.
Desktop Board Features
23