Refreshing The Switch Admin Module; Launching The Telnet Window; Accessing Telnet Through Advanced Web Tools; Configuring Ip And Netmask Information - HP StorageWorks 2/64 - Core Switch Administrator's Manual

Hp storageworks fabric os 5.x advanced web tools administrator guide (aa-rvhxb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

2.
Click the Admin button on the Switch View.
The Switch Admin module is displayed (as shown in

Refreshing the switch Admin Module

To refresh the fabric element information displayed at any time, click the Refresh button in any tabbed
page of the Switch Admin module.
When you click a different tab in the Switch Admin module, the information in the newly selected tab is
refreshed.

Launching the telnet window

When you launch a telnet window for the Core Switch 2/64, SAN Director 2/128, or 4/256 SAN
Director, the launch is on a logical-switch basis. This means that for each logical switch, you must launch
a separate telnet window. See the HP StorageWorks Fabric OS 5.x command reference guide for
information about the telnet commands.
NOTE:
Advanced Web Tools does not support telnet on the Mozilla browser. You must use an external
CLI if using Mozilla.
Telnet access to a switch and the Telnet button in Advanced Web Tools are both disabled when secure
mode is enabled for a fabric. You must use sectelnet or SSH to access the Fabric OS CLI in a secure
fabric. These capabilities are not accessible from Advanced Web Tools. For more information on
sectelnet or SSH, see the HP StorageWorks Secure Fabric OS administrator guide.

Accessing telnet through Advanced Web Tools

1.
Select a switch from the Fabric Tree.
The selected switch appears in the Switch View.
2.
Click the Telnet button on the Switch View.
The Telnet window opens.
3.
To close the session when you are done, issue the exit command at the telnet prompt.

Configuring IP and netmask information

When you configure IP address and netmask information for the Core Switch 2/64, SAN Director
2/128, or 4/256 SAN Director, the configuration is on a logical-switch basis. This means that for each
logical switch, you must configure IP and subnet mask information individually.
When changing the Ethernet IP/netmask, the Gateway IP, or the Fibre Channel net IP/netmask from
Advanced Web Tools, there is a normal loss of network connection to the switch. If the IP properties have
changed, you must close all current windows and restart Advanced Web Tools with the new IP address.
Configuring IP and netmask information
1.
Launch the Switch Admin module as described in
2.
Click the Network tab (see
3.
Enter a new value in the appropriate field (for example, 10.77.77.77).
4.
For the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director only:
a. Click Advanced.
b. Enter a valid IP addresses for the Ethernet IP addresses and subnet mask for CP0 and CP1.
c. Click OK to return to the Network tab.
5.
Click Apply.
6.
Exit and relaunch Advanced Web Tools to continue working.
"Launching the switch Admin Module" on page
Figure
8).
Fabric OS 5.x Advanced Web Tools administrator guide
Figure 7
on page 36).
36.
37