Gigabyte GA-Z77-D3H User Manual page 87

Gigabyte - atx motherboard 1600/1333/1066mhz (socket 1155)
Hide thumbs Also See for GA-Z77-D3H:
Table of Contents

Advertisement

C. Rebuilding an Array
Rebuilding is the process of restoring data to a hard drive from other drives in the array. Rebuilding applies only
to fault-tolerant arrays such as RAID 1, RAID 5 or RAID 10 arrays. The procedures below assume a new drive
is added to replace a failed drive to rebuild a RAID 1 array. (Note: The new drive must have equal or greater
capacity than the old one.)
Turn off your computer and replace the failed hard drive with a new one. Restart your computer.
Enabling Automatic Rebuild
Step 1:
When the message "Press <Ctrl-I> to enter Configuration Utility" appears, press <Ctrl> + <I> to enter the RAID
Configuration Utility. The following screen appears after you enter the RAID Configuration Utility.
Intel(R) Rapid Storage Technology - Option ROM - 11.0.0.1339
Copyright(C) 2003-11 Intel Corporation. All Rights Reserved.
1. Create RAID Volume
2. Delete RAID Volume
"Degraded volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
RAID Volumes :
ID
Drive Model
None defined.
1
WDC WD800JD-22LS
Physical Disks :
[hi]-Previous/Next
ID
Drive Model
0
ST3120026AS
1
WDC WD800JD-22LS
[hi]-Select
Step 2:
Select the new hard drive to add into the array to be rebuilt and press <Enter>. The following screen appears,
indicating that an automatic rebuild will be performed after you enter the operating system (look for the Intel
Rapid Storage Technology icon
If you do not enable automatic rebuild on this stage, you have to manually rebuild the array in the operating
system (see the next page for more details).
Intel(R) Rapid Storage Technology - Option ROM - 11.0.0.1339
Copyright(C) 2003-11 Intel Corporation. All Rights Reserved.
1. Create RAID Volume
2. Delete RAID Volume
3. Reset Disks to Non-RAID
RAID Volumes :
ID
Name
Level
0
Volume0
RAID1(Mirror)
Physical Devices :
ID
Devices Model
0
ST3120026AS
1
WDC WD800JD-22LS
Volumes with "Rebuild" status will be rebuilt within the operating system.
[hi]-Select
[ MAIN MENU ]
[
DEGRADED VOLUME DETECTED
[ DISK/VOLUME INFORMATION ]
Serial #
WD-WMAM9W736333
[ENTER]-Select
Serial #
Size
3JT354CP
111.7GB
WD-WMAM9W736333
111.7GB
[ESC]-Exit
in the notification area, which will show that a RAID volume is being rebuilt).
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION ]
Strip
Size
N/A
111.7GB
Serial #
Size
3JT354CP
111.7GB
WD-WMAM9W736333
111.7GB
[ESC]-Exit
- 87 -
]
3. Reset Disks to Non-RAID
4. Exit
Size
111.7GB
[ESC]-Exit
Type/Status(Vol ID)
Member Disk (0)
Non-RAID Disk
[ENTER]-Select Menu
4. Recovery Volume Options
5. Acceleration Options
6. Exit
Status
Bootable
Rebuild
Yes
Type/Status(Vol ID)
Member Disk (0)
Member Disk (0)
[ENTER]-Select Menu
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga-h77-d3h-mvpGa-h77-d3h

Table of Contents