Before You Run Your Vehicle Using Your Edelbrock Nitrous System; Fuel System Check; Nitrous System Check - Edelbrock 70211 Installation Manual

2002-2003 ecotec 2.2l performer efi nitrous system
Table of Contents

Advertisement

4.0

Before You Run Your Vehicle Using Your Edelbrock Nitrous System

You have just completed the installation of your Edelbrock Nitrous System. It is time to perform some basic system checks
to ensure all of the work you have done is correct and ready to operate properly. The following procedure is designed to
validate the operation of your nitrous system before operating your vehicle:
Note: Before performing steps 1 through 4, make sure that the nitrous bottle is closed and main nitrous supply
line is empty of any nitrous.
4.1

Fuel System Check

1. Hook up all battery leads.
2. Double-check all wires and leads for signs of heat and proper connections.
3. Start your vehicle.
4. Check all fittings for leaks.
4.2

Nitrous System Check

1.
With the vehicle's engine running, slowly open nitrous bottle valve.
Note: There should be no change in engine idle speed. If idle speed changes, close nitrous bottle valve
immediately and refer to the "Troubleshooting Guide" section.
2.
Inspect nitrous lines and fittings for leaks using a soapy water mixture and a small brush.
3.
If any of the fittings/connections show bubbling around the attachment nut or on the threaded area of the
fitting, shut the nitrous bottle valve off immediately and dry the fitting before attempting any service to that
particular fitting connection.
4.
If the engine idle does not come up, and all of the fittings appear to be leak-free, you have successfully
completed the installation of you Edelbrock Nitrous System.
©2003 Edelbrock Corporation
Brochure No. 63-0173
Page 19 of 23
Rev. 02/03