The following table lists the system sensor's threshold settings and formulas
for converting the sensor readings.
Table 1-47. Threshold Settings and Converting Formulas
Sensor
Sensor Name
Number
Voltage
05h
12 V Standby Actual_Reading (Volts) = ((Raw_Data x 65) + 60) x 0.001
06h
5 V
07h
5 V Standby
08h
3.3 V
09h
3.3 V Standby Actual_Reading (Volts) = ((Raw_Data x 197) + 100) x
62
Manual\BMC\C8000_BMC_HOM_section1.fm
The Converting Formula
Upper non-
Upper
recoverable
critical
D4
CA
Actual_Reading (Volts) = ((Raw_Data x276) + 100) x
0.0001
D0
C7
Actual_Reading (Volts) = ((Raw_Data x 277) + 80) x
0.0001
D0
C7
Actual_Reading (Volts) = ((Raw_Data x 199) + 70) x
0.0001
BF
B7
0.0001
C1
B9
Upper
Lower non-
non-
recoverable
critical
C1
9C
BE
9A
BE
9A
AE
8D
B0
8F
Lower
Lower
critical
non-
critical
A6
AF
A3
AC
A3
AC
95
9E
97