12. TABLE OF ERROR CODES
Code
Sewing machine motor stopped due to a problem, or synchronizer is faulty.
E130
Turn off the power, and then turn the machine pulley and check if the sewing machine has locked up.
Check that connectors P4 and P5 on the power supply motor P.C. board are properly connected.
Synchronizer is faulty.
E131
Turn off the power, and then check that connector P5 on the power supply motor P. C. board is properly
connected.
Problem detected with sewing machine motor operation.
E132
Turn off the power, and then check that connector P4 on the power supply motor P.C. board is properly
connected.
Sewing machine motor stopping position is incorrect.
E133
Turn off the power, and then check that connector P5 on the power supply motor P.C. board is properly
connected.
Sewing machine motor is overheating, or temperature sensor is faulty.
Turn off the power, and then check the sewing machine motor.
E150
(When sewing data with a small number of stitches (15 stitches or less) is sewn repeatedly (short cycle
operation), the upper shaft motor may overheat and the "E150" error code may be generated.)
Feed mechanism-related errors
Code
X-feed motor home position cannot be detected.
Problem with X -feed motor or poor X home position sensor connection.
E200
Turn off the power, and then check that connector P10 on the PMD P.C. board and connector P20 on the main
P.C. board are properly connected.
X-feed motor stopped due to a problem.
E201
Turn off the power, and then check if there are any problems in the X-feed direction.
Problem with X-feed motor or Y-feed motor home position adjustment data.
E202
Re-adjust the home position.
X feed motor stopped abnormally during sewing.
E204
Turn off the power, and then check if there are any problems in the X-feed direction.
X feed motor stopped abnormally while moving to the sewing start position.
E205
Turn off the power, and then check if there are any problems in the X-feed direction.
X feed motor stopped abnormally during test feeding.
E206
Turn off the power, and then check if there are any problems in the X-feed direction.
X feed motor stopped abnormally during programming.
E207
Turn off the power, and then check if there are any problems in the X-feed direction.
Y-feed motor home position cannot be detected.
Problem with Y-feed motor or poor Y home position sensor connection.
E210
Turn off the power, and then check that connector P8 on the PMD P.C. board and connector P4 on the main P.C.
board are properly connected.
Y-feed motor stopped due to a problem.
E211
Turn off the power, and then check if there are any problems in the Y-feed direction.
Y feed motor stopped abnormally during sewing.
E214
Turn off the power, and then check if there are any problems in the Y-feed direction.
Y feed motor stopped abnormally while moving to the sewing start position.
E215
Turn off the power, and then check if there are any problems in the Y-feed direction.
Y feed motor stopped abnormally during test feeding.
E216
Turn off the power, and then check if there are any problems in the Y-feed direction.
Y feed motor stopped abnormally during programming.
E217
Turn off the power, and then check if there are any problems in the Y-feed direction.
Work clamp-related errors
Code
Work clamp home position cannot be detected.
Problem with work clamp motor or poor work clamp home position sensor connection.
E300
Turn off the power, and then check that connector P3 on the PMD P.C. board and connector P5 on the main P.C.
board are properly connected.
Intermittent presser foot raised or lowered position cannot be detected.
E301
Turn off the power, and then check if there are any problems in the intermittent presser foot vertical direction.
Problem with work clamp motor home position adjustment data.
E303
Re-adjust the home position.