Download Print this page

Maytag MER8875W - 30 in. Ing Electric Range Installation Instructions Manual page 8

30" (76.0 cm) free standing electric ranges
Hide thumbs Also See for MER8875W - 30 in. Ing Electric Range:

Advertisement

3=
Feed the power supply cord through the strain relief on the
cord/conduit
plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A
....................
B
E
D
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Power supply cord wires - large opening
E. Small opening
4. Use Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw. The ground wire must be attached first.
5. Use 3/8"nut driver to connect the neutral (white) wire to the
center terminal block post with one of the #10-32 hex nuts.
A
B
.... t
Ei
C
D
A. #10-32 hex nut
B. Ground-link
screw
C. Line 1 (black)
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
6. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with #10-32 hex nuts.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 13/8"(3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Replace terminal block access cover.
3-wire connection:
Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the
cord/conduit
plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A
.....................
i/'
,'
i
B
2=
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Power supply cord wires - large opening
E. Smafl opening
Use 3/8"nut driver to connect the neutral (white) wire to the
center terminal block post with one of the #10-32 hex nuts.
B
C
A. #10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
E
D. Neutral (white) wire
E. Line 2 (red)
3. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with #10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 13/8"(3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5. Replace terminal block access cover.