30" (76.0 cm) free standing electric ranges
Hide thumbs Also See for MER8875W - 30 in. Ing Electric Range:

Advertisement

The fourth (grounding)
conductor must b eidentified byagreen o r
green/yellow
cover a ndtheneutral conductor byawhite cover.
Cord should beType SRD orSRDT w itha ULlisted strain relief
andbeatleast 4 ft (1.22 m)long.
@
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting
to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord
contains 3 copper conductors
with ring terminals or open-end
spade terminals with upturned ends, terminating
in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
@
3-wire
receptacle
(10-50R)
INSTALLATION INSTRUCTIONS
Unpc c
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1=
2.
3.
4=
On Ranges Equipped with Storage Drawers:
Remove the storage drawer. If a range height adjustment is
necessary, use a 1¼,, d rive ratchet to lower the rear leveling
legs one-half turn. Use a wrench or pliers to lower front
leveling legs.
A
D
Remove shipping materials, tape and film from range.
Remove oven racks and parts package from inside oven.
Do not remove the shipping base at this time.
A. Shipping base
B
A. ¼" drive ratchet
B. Rear levering leg
C. Wrench or priers
D. Front levering leg
On Ranges Equipped with Warming Drawers:
If a range height adjustment is necessary, use wrench or pliers
to lower the front and rear leveling legs.
A
B
A. Rear levering leg
B. Front levering leg
C. Wrench or priers

Advertisement