9) "24" [CR]
Status: Processing Power Save / Cooling Down
When Power Management function is ON in setting menu and there is no signal for 5
minutes, it moves on to Power Save/Cooling Down after tuning off the lamps. (During
this process, Green LED is OFF.)
The control command is invalid
After this Power Save/Coolign Down continues for about 90 seconds, it moves on to
Power Save.(Green LED flashes.)
Status:
Response
10) "04" [CR]
Status of Power Save
When the Power Management function is ON in setting menu, and there is no
signal for 5 minutes, it moves on to PowerSave status after PowerSave and Cooling
Down.
Moving on to the status of Power On is the same action as moving on to the Power
On from the status of normal stand by.
Moving on to the status of Power On is the same action as moving on to the Power
On from the status of normal stand by.

8.4. Input Mode Read Command

Command
Detail
Response
8.5. Lamp Time Read Command
Command
Detail
Response
No signal
Power Save / Cooling Down
"00"
After 5 minutes with no signal
・Power ON Command:"C00"[CR] ・・・・・・・・move on the status of power on
・Power OFF Command:"C01"[CR] ・・・・・move on the status of stand by
"CR1" [CR]
Get selected Input No.
Acceptable
"%1" [CR]
"1" = Computer is selected
%1
"3" = Video is selected
Unacceptable
"?" [CR]
"CR3" [CR]
Get total lamp running hours.
Acceptable
"%1" [CR]
Show as 4 digits
%1
Ex.: "0410"[CR] !410 hours
Unacceptable
"?" [CR]
"24"
after about 90 seconds
Page 17 of 18
Power Save
"04"