Sharp R-230HW Service Manual page 19

Service manual
Hide thumbs Also See for R-230HW:
Table of Contents

Advertisement

PROCEDURE
LETTER
STEPS
1
2
5) Make a visual inspection of the varistor.
Check for burned damage and examine the
transformer with a tester for the presence of
layer short-circuit (check the primary coil
resistance which is approximately 915
10%). If any abnormal condition is detected,
replace the control unit.
6) Reconnect all leads removed from components during testing.
7) Re-install the outer case (cabinet).
8) Reconnect the power supply cord after the outer case is installed.
9) Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if indicator does not light up after above check and
repairs are finished.
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using
insulation tape.
6) After that procedure, re-connect the power supply cord.
7) Follow the troubleshooting guide given below for repair.
STEPS
1
2
8) Disconnect the power supply cord and then remove outer case.
9) Open the door and block it open.
10) Discharge high voltage capacitor.
11) Reconnect all leads removed from components during testing.
12) Re-install the outer case (cabinet).
13) Reconnect the power supply cord after the outer case is installed.
14) Run the oven and check all functions.
TEST PROCEDURES
COMPONENT TEST
OCCURRENCE
Only pattern at "a" is broken.
Pattern at "a" and "b" are broken.
OCCURRENCE
The rated AC voltage is not present between
Pin No. 3 of the 2-pin connector (A) and the
normal open terminal of the relay RY2.
The rated AC voltage is present at primary
side of low voltage transformer.
17
CAUSE OR CORRECTION
*Insert jumper wire J1 and solder.
*Insert the coil RCILF2003YAZZ between "c" and "d".
d
a
(J1)
c
CAUSE OR CORRECTION
Check supply voltage and oven power cord.
Low voltage transformer or secondary circuit defective.
Check and replace control unit.
R-203HW
R-220HW
R-230HW
b
T1

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-201fwR-220fwR-203hwR-220hw

Table of Contents