A.O. Smith TC-049R3 Service Handbook page 40

A.o. smith residential gas and electric water heater service handbook
Table of Contents

Advertisement

RESIDENTIAL GAS AND ELECTRIC WATER HEATER
Residential Electric – continued
C-2 – service continued
Complaint:
Conditions:
Procedure:
AC voltage check
Test voltage between 1 and 3 or L1 and L3 of high limit.
If ...
rated voltage is not present
rated voltage is present
Test voltage between 2 and 4 or L1 and L4 of high limit
If ...
rated voltage is not present
rated voltage is present
Test voltage between 4 and 2 or T2 and L4
If ...
rated voltage is not present
rated voltage is present
A.O. Smith Water Products Company
©2005
SERVICE HANDBOOK
No Hot Water
Tank water cold
Power on
Multimeter set for
Voltage Checks
... then
continue to next step.
... then
continue to next step.
... then
continue to next step.
39
check circuit breaker (fused disconnect)
check wire connections in heater junction
box
check position of heater ON/OFF switch-if
applicable.
press high limit reset button
replace high limit (after conducting
thermostat check)
check jumper between high limit 2 and
thermostat 1or
on T2, L4 test-replace control.
Technical Training Department