HP AA979A - StorageWorks SAN Switch 2/8V Administrator's Manual page 214

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, november 2009)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

5.
After identifying such ports, enter the portCfgPersistentEnable command to enable the port,
and then the portCfgShow command to verify the port is enabled.
switch:admin_06> portcfgpersistentenable 7/10
switch:admin_06> portcfgshow 7/10
Area Number:
Speed Level:
Trunk Port
Long Distance
VC Link Init
Locked L_Port
Locked G_Port
Disabled E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable
NPIV capability
EX Port
Mirror Port
6.
Enter either the portCfgEXPort or portShow command to verify that each port is configured
correctly:
switch:admin_06> portcfgexport 7/10
Admin:
State:
Pid format:
Operate mode:
Edge Fabric ID:
Preferred Domain ID:
Front WWN:
Fabric Parameters:
R_A_TOV:
E_D_TOV:
Authentication Type: None
DH Group: N/A
Hash Algorithm: N/A
Edge fabric's primary wwn: N/A
Edge fabric's version stamp: N/A
214 Using the FC-FC routing service
74
AUTO
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
Port
7/10
info
enabled
NOT OK
Not Applicable
Brocade Native
30
160
50:06:06:9e:20:38:6e:1e
Auto Negotiate
Not Applicable
Not Applicable