OPERATION AND MAINTENANCE

MANUAL DISCONNECT

Release the handle on the operator arm to allow the gate to be opened and closed
manually. On a dual gate application the handle must be released on both operators.
To resume normal function tighten the handle by pushing it down.

RESET BUTTON

The reset button is located on the front of the operator and serves several functions.
Pressing the reset button will stop a moving gate during a normal open/close cycle,
like a stop button. The operator does not need to be reset after doing this.
PROGRAMMING LIMITS RESET
If a mistake is made while programming the limits press the reset button to
start over.
OPERATOR ALARM
If a contact sensor detects an obstruction twice consecutively the alarm will sound
(up to 5 minutes) and the operator will need to be reset.
When the inherent force of the operator (RPM/current sensor) detects the
following (twice consecutively) the alarm will sound (up to 5 minutes) and the
operator will need to be reset:
A. The operator arm or gate is incorrectly installed.
B. The gate does not meet specifications.
C. Gate hinges are too tight or broken and the gate is not moving freely.
D. The gate is moving and a car pushes the gate.
E. A foreign object is on the gate frame while the gate is moving.
F. The gate hits the driveway, curb or other, and gets stuck or bent in an
awkward position.
Remove any obstructions. Press the reset button to shut off the alarm and reset
the operator. After the operator is reset, normal functions will resume.
NOTE: In dual gate applications the reset button must be pressed on the
primary operator.

REMOTE CONTROL

Once the remote control has been programmed operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open
the gate. During the open cycle another activation of the remote control will stop the
gate and the next activation of the remote control will close the gate.
When the gate is in the open position, activation of the remote control button will
close the gate.

SLEEP MODE

The operator enters sleep mode 15 seconds after the last command is given. The
diagnostic LED will blink in this mode. The photoelectric sensor indicator LEDs will not
be on. The next command given will return the operator to normal operation.
» MANUAL DISCONNECT + RESET BUTTON + REMOTE CONTROL +