Problems With Zoning - HP 316095-B21 - StorageWorks Edge Switch 2/24 User Manual

Hafm sw 08.08.00 hp storageworks ha-fabric manager user guide (aa-rs2ch-te, august 2006)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Table 28
Zoning problems and resolutions
Problem
Receiving zoning errors.
The application is not performing
zoning discovery very often.
When activating a large zone set
on a two-switch fabric on UNIX
platforms, an error message is
displayed stating Failed to
perform the requested
zoning action: Failed to
zone due to exception
COM.hp.hafmecc.HafmUnava
ilableException.
Zoning activation message is
displayed for a long time, but
zone set is not activated.
When opening the Zoning dialog
box from a particular switch or
fabric, the message Cannot
zone the selected device
or fabric is displayed.
Cause/resolution
Verify that you did not configure zoning on a
non-principal switch.
Zoning discovery is performed once at startup, and
then once every two hours during routine discovery. If
the Zoning dialog box is open, zoning discovery is
performed during every polling cycle. It continues to
discover at the increased speed for 30 minutes
before it returns to the default value.
Although the error message states that the requested
zoning action failed, the zone set correctly activated.
Wait for the next zoning polling to occur.
Telnet zoning can take a long time. To improve
speed, open the Discover Setup dialog box and add
the HAFM IP address for HP switches to the Selected
Individual Addresses list.
The application can have been unable to log in to
the fabric due to another active session. Verify that
there is not another active session.
The application cannot support zoning on any of the
discovered products.
HA-Fabric Manager user guide 217