HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Replacement Instructions

Hp storageworks msa1500 cs/msa20 power supply replacement instructions (april 2004)
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:

Advertisement

hp StorageWorks
MSA1500 cs/MSA20

Power Supply

These instructions apply to the MSA1500 cs
and MSA20 product families. The part may
also be used in other HP products. Please
refer to documentation for your specific
product for detailed replacement
instructions.
If the product in which this part is being replaced is still under HP
warranty, then the replacement part(s) referred to in these Replacement
Instructions is provided under the terms and conditions of the
Hewlett-Packard Company Limited Warranty for that product. A copy of
this Limited Warranty may be viewed at:
http://h18006.www1.hp.com/products/storageworks/warranty.html
If this is a trade sale part (product out of warranty), then the replacement
part(s) referred to in these Replacement Instructions is provided under HP's
express limited warranty statement, which may be viewed at:
http://customerops.corp.hp.com/1sw/pdm_om/warranty_support/policies/
2330100.doc
The replacement part takes on either the Limited Warranty Period of the
part being replaced or a ninety-day period that begins upon installation
of the replacement part, whichever is greater.
The information contained on these replacement instructions is subject to
change without notice. The only warranty for this replacement product is
as noted above. Nothing in these replacement instructions should be
construed as constituting an additional warranty. The information
provided in these replacement instructions is provided "AS IS" and HP is
not liable for technical or editorial errors or omissions contained herein.
© Copyright 2004 Hewlett-Packard Development Company, L.P.
Please note that this document is protected by federal copyright law and
that no part of this document may be copied, reproduced or translated
without the prior written consent of Hewlett-Packard Development
Company, L.P.
Printed in Singapore.
MSA1500 cs/MSA20 Power Supply Replacement Instructions
First Edition (April 2004)
Part Number: 361699-001
Replacement
Instructions
361699- 001
About this document
This document details the procedures for replacing a failed
power supply in an MSA1500 cs or MSA20 storage product.

Verifying component failure

Before replacing the power supply, use the following methods
to verify the component failure.
MSA1500 cs
Check the controller LCD for the error message listed in
Table
1.
Table 1: LCD Error Message
No.
409
STORAGE BOX #<n> POWER SUPPLY FAILED
MSA20
The enclosure fault indicator is amber 1.
Figure 1: MSA20 enclosure fault indicator
MSA1500 cs and MSA20
The power supply indicator on the rear of the module is
flashing amber. 1
The system has power but the power supply indicator on
the rear of the module is off 1.
Figure 2: Power supply indicator
Message
1
1

Advertisement

loading

Summary of Contents for HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive

  • Page 1: Verifying Component Failure

    Replacement Instructions is provided under the terms and conditions of the Figure 1: MSA20 enclosure fault indicator Hewlett-Packard Company Limited Warranty for that product. A copy of this Limited Warranty may be viewed at: MSA1500 cs and MSA20 http://h18006.www1.hp.com/products/storageworks/warranty.html...
  • Page 2 Before you begin Step 2: Installing the power supply Read the following cautions and information before beginning 1. Remove any connector protector that may be covering the removal and replacement procedures. power connector on the front of the new power supply. 2.