Chamberlain LGJ Owner's Manual page 15

Industrial duty door operator
Table of Contents

Advertisement

NUMBERED BOXES CORRESPOND WITH TERMINALS ON J1 CONNECTOR STRIP
If Neccessary, Remove The Connector Block From The Board To Secure Each Wire Connection
Connect field wires to any terminal number shown in the respective column. See control
options below for explanation of how field control will function for each terminal number.
11
OR
7
9
OR
OR
4
8
OPEN
CLOSE
STOP
STANDARD
3 BUTTON CONTROL
OR
OR
4
11
5
OPEN
CLOSE
2 BUTTON
CONTROL
(SEE NOTE)
IMPORTANT NOTE:
OPEN AND CLOSE CONTROL OPTIONS
11
WHEN CONNECTING AN
OPEN CONTROL TO:
9
8
4
WHEN CONNECTING AN
CLOSE CONTROL TO:
7
LGJ CONTROL CONNECTION DIAGRAM
5
3
10
SENSING
EDGE
11
OR
7
9
OR
OR
4
8
5
3
OPEN
CLOSE
STOP
OFF
ON
3 BUTTON CONTROL
WITH
KEYED LOCK-OUT
WHEN STOP BUTTON IS NOT USED, ADD A JUMPER FROM
TERMINAL 3 TO TERMINAL 5.
- Open control will require constant
pressure to keep door moving.
- Open control will only require
momentary contact and will set or
reset timer to close.
- Open control will only require
momentary contact and will NOT
set or reset timer to close.
- Close control will require constant
pressure to keep door moving.
- Close control will only require
momentary contact.
DO NOT add unless using an
entrapment Protection device.
11
OR
9
OR
5
8
5
ANY OPEN
CONTROL
(SEE NOTE)
11
OR
7
9
OR
OR
4
8
5
OPEN
CLOSE
STOP
3 BUTTON CONTROL
MULTIPLE CONTROL STATIONS
SWITCH ADJUSTMENTS
MAXIMUM RUN TIME: 1 - ON: Maximum run time is 90 seconds.
MAXIMUM RUN TIME: 2 - ON: CLOSE limit switch B
MAXIMUM RUN TIME: 3 - OFF: (DO NOT ADJUST)
TIMER TO CLOSE SWITCH SETTING:
SETTING
1 2 3 4
O O O O
F O O O
O F O O
F F O O
O O F O
F O F O
O F F O
F F F O
15
41B6
LISTED DOOR OPERATOR
6
5
ANY
OPEN & CLOSE
CONTROL
(SEE NOTE)
11
OR
7
9
OR
OR
4
8
5
OPEN
CLOSE
STOP
WITH
3
5
SWITCH #1 SETTINGS
OFF: Maximum run time is 45 seconds.
OFF: CLOSE limit switch A
4 - OFF: (DO NOT ADJUST)
CONSULT FACTORY FOR ADJUSTEMENT
SWITCH #2 SETTINGS
O = ON F = OFF
TIME
SETTING
TIME
1 2 3 4
= Disabled
= 72 sec
O O O F
= 2 sec
= 88 sec
F O O F
= 3 sec
= 107 sec
O F O F
= 13 sec
= 126sec
F F O F
= 15 sec
= 148 sec
O O F F
= 23 sec
= 172 sec
F O F F
= 32.5 sec
= 198 sec
O F F F
= 43.6 sec
= 224 sec
F F F F
3