SINGLE PHASE SCHEMATIC DIAGRAM for MGJ
(OPTIONAL)
LIGHT
MAX.
100W
BK
W
BK
(HOT) L2
R
BK
3
STOP
4
MOVE JUMPER WIRE TO TERMINAL #2
FOR MOMENTARY CONTACT ON CLOSE
BR
R1
OPEN
SAFETY
EDGE
10
GY
GY
PULL SWITCH
TO
OPEN & CLOSE
7
CLOSE
* TO REVERSE MOTOR ROTATION INTERCHANGE
RED AND YELLOW MOTOR WIRES.
(OPTIONAL)
BIMETAL
RELAY
W
C
WIRE NUT
CLOSE-B
BL
C
N.O.
RES.
OPEN-A
CAPACITOR
Y
BL
BR
OPEN-B
OR
1
AUX.
CLOSE L/S
OR
GY
AUX.
Y
Y
OPEN
R2
L/S
P
2
12
B
A
Y
MOTOR *
Y
Y
R
PR1.
24VAC.
SEC.
R
CLOSE-A
12
BL
C
N.O.
OR
OP
P
CL
1754
W
BK
L1 (N)
O/L
BR
WIRE NUT
W
10VA.
Y/BK
R3
R
OPEN L.S.
11
W
OR
N.C.
C
W
CLOSE L/S
W
P
N.C.
C