"DEDICATED"
TELEPHONE LINE
VEHICULAR GATE
W X Y
9
Connect the two yellow wires to the main
vehicular gate operator or door. The gate/door
will be activated by either pressing 9 from the
residents side, or by using a utility keycode,
individual keycode or optional RF transmitter
from Entry Phone side. (Refer to page 12 &
13)
WIRING DIAGRAM
2 YELLOW WIRES
ENTRY 1
CONDUIT
MASTER GATE OPERATOR
(STRIKE OPEN INPUT)
ACCESS DOOR
OR
ELITE ENTRY PHONE
2 BLUE WIRES
ENTRY 2
LOCK
OR
W X Y
5
Connect the two blue wires to the secondary
gate or door. The gate/door will only be
activated from the residents side by pressing 5.
(Refer to page 27 to adjust the strike times).
MAX.
AWG
DISTANCE
24
170'
22
280'
20
450'
18
700'
16
1100'
12VAC 40VA
see chart above
for distance
BLACK/WHITE
PEDESTRIAN GATE
ENTRY DOOR
PAGE
9