Biostar P4 TDG Engineering Validation Test Report page 56

P4tdg compatibility test report
Hide thumbs Also See for P4 TDG:
Table of Contents

Advertisement

Blue cells need to be filled in with lab measurement
Yellow cells need to have the overall design tolerance entered
VID Voltage:
Tolerance:
+Tolerance
- Tolerance
Vdmm
Vscope
Vfb_nl
Static Voltage Measurements at pins AC14/AC15
Current
0
10
20
30
40
50
60
Ripple Voltage Measurements (mV) at pins AC14/AC15
Current
0
10
20
30
40
50
60
56
1.496
1.502
Measured Static Voltage
1.496
1.473
1.450
1.424
1.396
1.366
1.328
Measurement
4.200
5.600
5.600
9.800
12.800
13.000
14.400
1.5V
1.00%Overall
0.008V
0.008V
V
V
V
Units
V
V
V
V
V
V
V
Units
mV
mV
mV
mV
mV
mV
mV