Biostar P4 TDG Engineering Validation Test Report page 52

P4tdg compatibility test report
Hide thumbs Also See for P4 TDG:
Table of Contents

Advertisement

Blue cells need to be filled in with lab measurement
Yellow cells need to have the overall design tolerance entered
VID Voltage:
Tolerance:
+Tolerance
- Tolerance
Vdmm
Vscope
Vfb_nl
Static Voltage Measurements at pins AC14/AC15
Current
0
10
20
30
40
50
60
Ripple Voltage Measurements (mV) at pins AC14/AC15
Current
0
10
20
30
40
50
60
52
1.461
1.464
1.458
Measured Static Voltage
1.461
1.450
1.439
1.427
1.414
1.400
1.382
Measurement
5.000
4.600
4.800
5.200
6.000
6.600
7.400
1.475V
1.00%Overall
0.007V
0.007V
V
V
V
Units
V
V
V
V
V
V
V
Units
mV
mV
mV
mV
mV
mV
mV

Advertisement