Mobile Home Installation - GE GTUP240EMWW Installation Instructions Manual

Unitized electric washer/dryer
Table of Contents

Advertisement

CONNECTING APPLIANCE USING 4-WIRE
CONNECTION (MUST BE USED FOR

MOBILE HOME INSTALLATION)

NOTES: SInce January 1,1996, the National Electric code
requires that the new constructions utilize a 4-wire
connection to an electric dryer.
WARNING:
Only a 4-conductor cord shall be
used when the appliance is installed in a location where
grounding through the neutral conductor is prohibited.
Grounding through the neutral is prohibited for the new
branch-circuit installations, mobile homes, recreational
vehicles, and areas where local codes prohibit
grounding through the neutral conduction.
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
SCREWS
(3)
COVER
1. Turn off the circuit breaker (s) (30 amp) or remove the
dryer's circuit fuse at the electrical box.
2. Be sure the appliance cord is unplugged from the wall
receptacle.
3. Remove the power cord cover located at the lower
4. Remove and discard ground strap. Keep the green
ground screw for step 7.
5. Install 3/4 in. UL recognized strain relief to power cord
entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
7. Attach ground wire of power cord with the green
ground screw (hole above strain relief bracket). Tighten all
terminal block screws (3) completely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
WARNING:
COVER OFF OF THE TERMINAL BLOCK.
Installation Instructions
HOT
RELOCATE GREEN
WIRE
GROUND SCREW
HERE
GREEN OR
L 1
YELLOW WIRE
N
STRAIN
L 2
RELIEF
BRACKET
NEUTRAL
(White)
3/4", UL
HOT
RECOGNIZED
WIRE
STRAIN RELIEF
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
NEVER LEAVE THE
CONNECTING DRYER USING 3-WIRE
CONNECTION
COVER
1. Turn off the circuit breaker(s) (30 amp) or remove the
dryer's
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
3. Remove the power cord cover located at the lower
back.
4. Install 3/4 in. UL recognized strain relief to power cord
entry hole. Bring power cord through strain relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center
of the terminal block (marked N).
6. Be sure ground strap is connected to neutral (center)
terminal of block and to green ground screw on cabinet
rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
back.
8. Reinstall the cover.
WARNING:
COVER OFF OF THE TERMINAL BLOCK.
5
GROUND
GREEN
STRAP
GROUND
SCREW
HOT
WIRE
L 1
SCREWS
L 2
(3)
NEUTRAL
HOT
(White)
WIRE
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
NEVER LEAVE THE
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF

Advertisement