Gasketing; Ash Removal Using The Ash Drawer - Drolet ESCAPE 1800 DB03100 Owner's Manual

Epa wood stove
Hide thumbs Also See for ESCAPE 1800 DB03100:
Table of Contents

Advertisement

4.3

GASKETING

It is recommended that you change the door gasket (which makes your stove door air tight) once a
year, in order to insure good control over the combustion, maximum efficiency and security. To
change the door gasket, simply remove the damaged one. Carefully clean the gasket groove, apply a
high temperature silicone sold for this purpose, and install the new gasket. Use only the genuine
Drolet gasket. You may light up your stove again approximately 24 hours after having completed
this operation.
4.4

ASH REMOVAL USING THE ASH DRAWER

C
:
AUTION
ASHES CAN START FIRES
IN A COMBUSTIBLE CONTAINER
Whenever the ashes get 3 – 4" (76 – 102 mm) deep in the firebox, they should be emptied into the
ash drawer, using the following instructions:
• Make sure the fire is out, and the stove is cold.
• Lift the ash dump plug in the center of the firebox by hooking the poker through the loop
on the cover and lifting up.
• Push the ashes through the hole and leave an ash bed of approximately 1" deep on the
firebox bottom to help maintain a hot ember bed.
• Clear the ashes from the area where the ash dump plug normally sits so that it will
properly seat against the opening edges. Tap it down with your poker to ensure proper
seating.
• Ashes should be placed in a metal container with a tightly fitting lid. This closed container
should be placed on a non-combustible floor or on the ground, well away from all
combustible (heat sensitive) materials, pending final disposal.
• Cover the ash dump plug with the remaining ashes and continue operation of your stove as
usual.
• If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be
retained in the closed container until all cinders have thoroughly cooled. Do not place other
waste materials in the metal ash container.
If bright embers are glowing above the ash dump cap during a low or medium fire, air may be
leaking past the ash plug. If this is happening, a possible over fire hazard exists. The stove
should be shut down and allowed to cool. Properly seal the ash dump cap.
,
EVEN AFTER SEVERAL DAYS OF INACTIVITY
. R
EMOVE ASHES WHEN THE STOVE AND ASHES ARE COLD
. N
EVER DISPOSE OF ASHES
.

Advertisement

Table of Contents
loading

Table of Contents