1.6.2. Installation Configurations

a) Horizontally through wall

(Refer to figures 10, 11, or 12)
NOTE: Follow vent chimney manufacturer's instructions.
1. Position stove, adhering to clearances shown in Figures 1 & 2.
2. Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 5).
3. Always maintain 3" clearance from combustible materials.
4. Install Vent wall thimble per Vent manufacturer's instructions.
5. Attach enough piping to penetrate and extend at least 6 inches beyond the exterior wall. There should
always be at least one foot of vertical rise for each foot of horizontal run (see Appendix A). At least 3 feet of
vertical rise are needed in all cases. A longer vertical rise will favour a better exhaust.
6. To reduce the risk of smoke spillage, never terminate with a horizontal run. If your system terminates with a
horizontal run, add at least 3 feet of vertical rise (see Appendix A).
7. Attach cap and seal outside wall thimbles with non-hardening waterproof mastic.
Termination should not be located so that hot exhaust gases can be a hazard to children. Exhaust gases can
reach temperatures of 500ºF and cause serious burns if touched.
Do not locate terminations:
FIGURE 11
Venting through wall