Installation Of A Heat Radiation Shield - Drolet DB05130 Manual

Drolet wood stove owner' manual model db05130
Table of Contents

Advertisement

INSTALLATION OF A HEAT RADIATION SHIELD

Following the installation of a heat radiation shield, the clearances mentioned on the stove certification plate
may be reduced as stated in the following table.
TYPE OF PROTECTION
Minimal requirements:
0,013" (0,33 mm) sheet metal
with 1" (25.4mm) fire-proof braces
Ceramic tile or an equivalent fire-proof material
resting on fire-proof brackets spaced 1" (25.4mm)
apart by fire-proof braces
Ceramic tile or an equivalent fire-proof material built
on a fire-proof base resting on sheet metal of at
least 0,013" (0,33 mm) thick spaced 1" (25.4mm)
by fire-proof braces.
Solid bricks, spaced 1" (25.4mm) from the rear
wall using fire-proof braces.
Solid bricks, resting on sheet metal 0,013" (0,33
mm) thick spaced 1" (25.4mm) from the rear wall
using fire-proof braces.
**Example: 15 inches x (100% - 67%) = 4,95 inches.
This reduction in clearance, when in compliance, is accepted by insurance companies.
FOR BARON 2000SP USING THE ENVELOPE
It is strictly forbidden to connect the envelope to existing liners or existing floor registers
or grilles.
Reductions in clearance to a combustible wall (or
ceiling) and the heating device, %
SIDES AND
REAR\BACK
67%**
50%
67%
50%
67%
TOP
50%
33%
50%
N\A
N\A
8

Advertisement

Table of Contents
loading