CERTIFIED INSTALLATION
Certified installations require one roof vent and one lower
side vent.
For "Certified Vent System Kits" see page 15.
For further information contact your dealer or distributor.
NOTE: The upper vent should be
centered over the condenser coil
at the back of the refrigerator.
Minimum
ventilation
height
FIG. 9
METHODS OF INSTALLATION
The method of installation is shown in FIG. 9.
It is essential that all maximum or minimum dimensions
are strictly maintained, as the performance of the refrig-
erator is dependent on adequate flow of air over the rear
of the refrigerator.
VENTILATION HEIGHTS
Installation with roof
vent and lower side vent
Refrigerator
RM2652
RM2852
Condenser
Minimum ventilation
heights in:
Inches
mm
57-3/4
1465
63-3/4
1620
G
K
L
FIG. 10
N
M
CLEARANCES
Minimum clearances in inches to combustible materials
are:
G: Top
0
K: Side
0
L:
Bottom 0
M: Rear
0
N: See NOTE: Clearance "N" below.
NOTE: Clearance "M" is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N" is the distance between the bot-
tom of the lower side vent to the roof material. For ven-
tilation height, see table VENTILATION HEIGHTS.
See Figures 9 and 10.
K
NOTE: Wood Strip
MUST be in place
7