PROBLEM
PROBLEM
PROBLEM
PROBLEM
PROBLEM
(4)
Wet steam (Cont.)
(5)
Water accumulates in
base
(6)
Excessive noise or
vibration
(7)
Blower motor won't
start, machine won't
steam
CA
CA
USE
USE
CA
CAUSE
CA
USE
USE
4D
Strainer clogged
4E
Return line turned off
4F
Steam Cycle too long
4G
Improperly installed
steam lines
4H
Heavy condensate in
supply line
4I
Machine not
individually trapped
4J
Back pressure in return
line
5A
Steam too wet
5B
Leak in finned tube or
pipe fitting
5C
Leaking steam valve
6A
Foreign object in blower
wheel
6B
Blower wheel out of
balance
6C
Motor bearings bad
6D
Motor mount bent
6E
Blower wheel loose on
motor shaft
7A
No electrical power
Page 28
Page 28
Page 28
Page 28
Page 28
REMEDY
REMEDY
REMEDY
REMEDY
REMEDY
Inspect strainer and clean if
necessary.
Open valve in condensate
return line.
Reduce amount of time set on
steam timer.
Check steam line installation to
see that "risers" are installed,
as shown on installation
illustration.
Install a by-pass trap from
supply header to by-pass
condensate to return line.
Install a separate trap for each
machine.
Inspect all traps to see if one is
stuck open, or improperly
installed. Perform steps neces-
sary to make return line drain
by gravity to condensate return
tank. See that return tank is
adequately vented.
See wet steam above.
Inspect machine and repair or
replace any leaking parts.
See leaking steam valve (3).
Inspect wheel and remove any
foreign objects & lint.
Inspect wheel for loose balance
weights, out of round or dam-
age, replace if necessary.
Inspect motor to see if bearings
are tight and motor free
turning. Replace motor if
necessary.
Inspect motor mount to see if
machine has been dropped in
transit, bending the mount,
letting the blower wheel hit the
housing. If so, inspect blower
wheel for damage. Replace
either or both if necessary.
Check to see that wheel is
mounted in center of housing,
key is in keyway if used, and
both set screws tight.
Check electrical service and be
sure main switch is "ON" all
wires are tight and fuses are
good.