Environmental
Temperature range:
Operating
Storage
Relative humidity (maximum):
Operating
Storage
Maximum vibration (using a random
vibration spectrum that simulates
user environment):
Operating
Maximum shock (Measured with
hard drive in operating but not
accessing data status and a 3-ms half-
sine pulse for operating. Also
measured with hard drive in head-
parked position and a 2-ms halfsine
pulse for storage):
Operating
Storage
Maximum bench handling height
(Measured with hard drive in idle
mode, lifting the system by one
edge, placing the opposite edge on
the table and then releasing the
system to impact against the table):
Altitude (maximum):
Operating
Storage
0° to 35°C (32° to 95°F)
–40° to 65°C (–40° to 149°F)
10% to 90% (noncondensing)
5% to 90% (noncondensing)
0.66 GRMS
X & Y axes (parallel to system bottom): 30G
Z axis (perpendicular to system bottom): 40G
163 G
10 cm
–15.2 to 3048 m (–50 to 10,000 ft)
–15.2 to 10,668 m (–50 to 35,000 ft)
Specifications