Download Print this page

Denon AVR 2308CI - AV Receiver Manual page 26

Control protocol
Hide thumbs Also See for AVR 2308CI - AV Receiver:

Advertisement

EVENT
PARAMETER
PHONO
Z2
|
IPOD
SOURCE
**
ON
OFF
ON
Z2MU
OFF
Z2CV
FL **
FR **
The PARAMETER of Z2 EVENT : Uses two ASCII characters. (see page4 J) section)
The PARAMETER of Z2 EVENT : Invalid at AVC-2308 for JAPAN
function
MULTI ZONE-2 source change
---The name of PARAMETER is
the same as that of the time of SI COMMAND.
MULTI ZONE-2 mode cancel
MULTI ZONE-2 VOLUME change , **:10 to 99 by ASCII
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
MULTI ZONE-2 ON/OFF change
ZONE2 OUTPUT MUTE ON/OFF change
**:38 to 62 by ASCII , 50=0dB
**:38 to 62 by ASCII , 50=0dB
- 26 -
example
Z2PHONO<CR>
|
Z2IPOD<CR>
Z2SOURCE<CR>
Z280<CR>
Z2ON<CR>
Z2OFF<CR>
Z2MUON<CR>
Z2MUOFF<CR>
Z2CVFL 50<CR>
Z2CVFR 50<CR>